FGM-3303B Free-Standing Poly-Phase Meter Tester

Product Overview
Description:

The FGM-3303B is a complete, high-accuracy meter calibration and testing solution. It consists of a power supply and error processing unit (FGM-3303), and a Class 0.05 external reference standard Watt-hour meter (FGM-5303C) combined in a free-standing cabinet, with 3 meter hangers.

The Watt-hour meter is used as the power monitoring instrument and thus can deliver a high accuracy measurement, and the error processing unit allows automated testing of up to 3 meters.

The device can be computer controlled via the included testing software, or directly through the front control panel and colour LCD.

The supplied DLL library allows full control over the device which can be integrated into user-developed applications.

The device comprises of the following major components:
  • High-stability, poly-phase, computer-controlled power source
  • 3 x Integrated error processors
  • Grade 0.05 poly-phase standard Watt-hour meter operating as the power monitoring instrument
  • Free-standing, self-contained cabinet
  • Optical scanning heads

The device comprises of the following major components:
  • AC Voltage
  • AC Current
  • Power Factor
  • Active and Reactive Power
  • Frequency
Included Devices
FGM-3303 (See Separate Listing)

The high-stability, poly-phase, power supply and error processors are utilized from the FGM-3303 to allow automated measurement of the device under test.

Having three integrated error processors, up to three metering devices can be tested simultaneously.

FGM-5303

The high accuracy (Class 0.05) standard Watt-hour meter is utilized from the FGM-5303 as the power monitoring instrument for the FGM-3303B, substituting the built-in unit.

It comprises of a high-speed DSP, and separation of voltage and current inputs by a passive transformer, providing high accuracy and great stability.

Power Supply Specifications

Output Specifications

Output Parameter

Range

Maximum Distortion

Maximum Output Capacity

Voltage

57.7V/63.5V, 220V/240V

0.3% Max.

50VA Max.

Current

0.1A, 1A, 5A, 20A, 100A

0.3% Max

100VA Max. (For 100A range)

Adjustment

Output Parameter

Adjustment Range

Adjustment Fineness

Voltage

0% - 125% for each range

10%, 1%, 0.1%, 0.01%

Current

0% - 125% for each range

10%, 1%, 0.1%, 0.01%

Phase

0° - 359.99°

10%, 1%, 0.1%, 0.01%

Harmonics

Number of harmonic wave

Amplitude of harmonic wave

Phase of harmonic wave

2nd to 31st  

< 40% base-wave

0° - 359.99°

Power supply

Type

Voltage

Frequency

Maximum Power Consumption

AC Single-Phase

220/240V

50/60Hz

500W Max.

Power Meter Specifications

Input specifications

Input Mode

Amplitude Range

Selectable Range

Overloading Capacity

Input Load

Voltage

40V – 480V

60V, 120V, 240V, 480V

600V Max.

≤0.5mA (480V)

Current

0.01A – 100A

0.025A, 0.05A, 0.1A, 0.25A, 0.5A, 1A, 5A, 10A, 25A, 50A

150A Max.

≤0.3mΩ (20A -100A)

≤6.0 mΩ (0.01A – 10A)

Accuracy

Measurement Type

Load Type (Active/Reactive)

Accuracy

Power

Active

0.05%, 0.1% (P.F. ≥ 0.5)

Reactive

0.1%, 0.2% (P.F. ≥ 0.5)

Watt-Hour

Active

0.05%, 0.1% (P.F. ≥ 0.5)

Reactive

0.1%, 0.2% (P.F. ≥ 0.5)

Miscellaneous

Front Display Contents

  • Three-Phase Four-Line Voltage
  • Three-Phase Three-Line Voltage
  • Three-Phase Current
  • Active Power/Apparent Power/Reactive Power
  • Power Factor/Phase Angle
  • Input Signal Frequency

Display Digits

5

Operating Temperature Range

5°C – 40°C

Operating Relative Humidity

≤85% (No Corrosive Gases)